 2. Job Set-up Information ______________________  A. Referenced Information  -------------------------------------------------------------------------------REFERENCE DESIGNATION  ------------------------------------------------------------------------------- AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)  AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)  AMM 22-96-00-710-001 Operational Test of the AFS  AMM 27-22-51-000-001 Removal of the Rudder Trim Actuator (10CC)  AMM 27-22-51-400-001 Installation of the Rudder Trim Actuator (10CC)  AMM 27-23-51-000-001 Removal of the Rudder Travel Limitation Unit 4CC

R  AMM 27-23-51-400-001 Installation of the Rudder Travel-Limitation Unit 4CC ASM 22-67/01  3. Fault Confirmation __________________  A. Make sure that this(these) circuit breaker(s) is(are) closed:  -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION ------------------------------------------------------------------------------- 121VU AUTO FLT/FAC2/28VDC  5CC2 M19  B. Test  (1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 2.  (a) If the circuit breaker 5CC2 is open refer to Para. 4.B.

 4. Fault Isolation _______________

 A. If the circuit breaker 5CC2 is closed, and if the test gives the maintenance message AFS: FAC2:  - do a check for 28VDC at the FAC 2 (1CC2).  (1) If there is 28VDC:

 - replace the FAC-2 (1CC2), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).

 (2) If there is no 28VDC:

 - do a check of the wiring of the 28VDC signal from the circuit  breaker (5CC2) to the FAC 2 (1CC2). R - do a check of the wiring of the ground signal at the FAC 2 (1CC2) R pin AC/3.  (Ref. ASM 22-67/01).  (a) If there is no continuity:

 - repair the above wirings.

 (b) If there is continuity:

 - replace the C/B-AUTO FLT/FAC 2/28VDC (5CC2).  B. If the circuit breaker 5CC2 is open:  - close this circuit breaker.  (1) If this circuit breaker opens again:  - disconnect these three units:  LIMITATION UNIT-RUDDER TRAVEL (4CC)  ACTUATOR-RUDDER TRIM (10CC)  FAC-2 (1CC2)

 - close the circuit breaker 5CC2.

 (a) If this circuit breaker stays closed:

 - connect the units one by one until the circuit breaker 5CC2 opens again

 - replace the related unit: for LRU 4CC: (Ref. AMM TASK 27-23-51-000-001) and (Ref. AMM TASK 27-23-51-400-001) for LRU 10CC: (Ref. AMM TASK 27-22-51-000-001) and (Ref. AMM TASK 27-22-51-400-001) for LRU 1CC2: (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).

 (b) If this circuit breaker opens again:

 - do a check for a short to ground between the circuit breaker 5CC2 and the three units, (Ref. ASM 22-67/01).  1 If there is a short to ground: _ - repair the related wiring.  「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 205  Feb 01/05 CES

_  - replace the C/B-AUTO FLT/FAC 2/28VDC (5CC2).  (2) Connect all the units.  C. Do the test given in Para. 3.

 Loss of the FAC 1 GENERAL Bus  1. Possible Causes _______________  - FAC-1 (1CC1)

 - wiring of the FAC OWN (GENERAL BUS) from the FAC 1 (1CC1) to the first terminal block

 2. Job Set-up Information ______________________  A. Referenced Information  -------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------- AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)  AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)  AMM 22-96-00-710-001 Operational Test of the AFS  ASM 22-69/01

 3. Fault Confirmation

__________________  A. Test  (1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 1.  4. Fault Isolation _______________  A. If the test gives the maintenance message AFS: FAC1/C-M ARINC LINK:  - replace the FAC-1 (1CC1), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).  (1) If the fault continues:  - do a check and repair the wiring of the FAC OWN (GENERAL BUS) from the FAC 1 (1CC1) to the first terminal block, (Ref. ASM 22-69/01).   www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2

原标题:
57 个人收藏 收藏

评论交流

这位访客请「登录」后参与评论

相关推荐

  • 金价今日如何走?机构最新现货黄金日内技术点位分析

      经中国证券监督管理委员会证监许可[2023]263号文《关于核准浙江亚光科技股份有限公司首次公开发行股票的批复》核准,并经上海证券交易所同意,浙江亚光科技股份有限公司(以下简称“公司”或“亚光股份”)首次向社会公众发行人民币普通股3,350万股,于2023年3月15日在上海证券交易所主板挂牌上市,公司首次公开发行股票后的总股本为133,820,000股。
  • 美联储维持利率?两手准备进场黄金

      这一切究竟是怎么发生的?
  • 广东潮州通报3名小孩失踪:玩耍时被沙体掩埋窒息死亡

      实际上,冠名商权益的问题是一个历史遗留问题,一个很重要的原因是,在俱乐部中性名的过程中,作为一项新生事物,相关规定不严谨。目前俱乐部名称是非常杂乱的:其一,存在双行政区划的情况,比如广西平果、上海嘉定,广西和上海是省市级行政区划,嘉定是地市级行政区划,平果是县市级行政区划;其二,存在中性名双词组情况,比如江西黑马青年,黑马和青年是双词组;其三,存在只有行政区划,没有中性名的情况。
  • 美国107个贸易团体游说 反对特朗普对华关税计划

      在递交给旧金山法院的文件中,OpenAI坚决驳斥了马斯克提出的指控,明确指出公司并未违背任何协定。OpenAI强调,“正如诉讼文件所明确指出的,我们与马斯克之间并不存在所谓的创立合同,也未曾形成任何协议。”在此之前,OpenAI已经通过内部通讯和博客文章对马斯克的指责做出了回应。
  • 讲座报名:报志愿各分数段如何利用技巧上名校

      每年春季,拜登和他的幕僚都会为制定从当年10月1日到次年9月30日的财年预算草案,但因为众议院是由共和党所把持,普遍认为拜登的预算案在国会不可能获得通过。
  • 任泽平:诺贝尔经济学奖得主思想综述及对中国的启示

      2024升学季,需要提前做哪些准备?国际教育路线该如何结合家庭情况合理规划?多位资深专家将结合最新政策和以往大数据分析,拆解规划方案,并1V1答疑解惑。
  • 董登新:家庭理财何以陷入“赚快钱”阶段

      2月23日,“小米汽车定价策略曝光”的词条一度冲上微博热搜。有媒体报道称,有接近雷军的小米前期员工透露称,“雷军正在憋大招,首批购买小米汽车的车主,如果没有北京牌照,可能会赠送牌照。”随后,小米公司发言人官方微博表示:“完全失实。小米汽车定价、交付及销售政策均以官方发布为准,望周知。”
  • 土超女排PTT苦战2

      今年是宁夏回族自治区成立60周年。对于宁夏的发展,习近平总书记有着一份特殊的牵挂。1997年4月,作为福建省委副书记、同时也是福建省对口帮扶宁夏领导小组组长的习近平第一次来到宁夏。此后,他曾于2008年和2016年两次来宁夏视察。
  • 京良收费站由堵变畅 云星宇探索“无人化”建设

      在运营理念方面,社区将根据实际发展情况不断灵活调整。例如目前房型70%为自理区,30%为护理区,但后期护理区的需求可能会增加,因此需要不断调整适应。同时,也需尽快建立起养老社区标准化管理体系,借鉴成功经验,完善培训考核标准,形成管理闭环。
  • 苹果打喷嚏中国女首富就重感冒:60亿4个小时就没了

      面对股价连续大跌,药明康德2月2日抛出了10亿元的回购股份计划,并于2月5日晚公告回购计划完成,回购股份数为2027.54万股。10亿元回购计划一天内完成,凸显公司高效。2月6日,药明康德的股价大幅反弹,随后稳定在53元/股左右。